ELECTRICAL SPECIFICATION

Device type
Class 1 Generation 2 passive UHF RFID transponder
Air interface protocol
EPCGlobal Class1 Gen2 ISO 18000-6C
Operational frequency
EU 865 – 869 MHz
US 902 – 928 MHz
IC type ETSI
NXP UCODE G2iM+
Memory: EPC 448 bit; User 640 bit; TID 96 bit
IC type FCC
Impinj Monza4QT
Memory: EPC 128 bit; User 512 bit; TID 96 bit
EPC memory content
Unique number encoded as a default
Read range (2W ERP)*
On metal up to 18m / 60ft
Other materials up to 16m / 52 ft
Applicable surface materials*
All surfaces


* Read ranges are theoretical values that are calculated for non-reflective
environment, in where antennas with optimum directivity are used with
maximum allowed operating power according to ETSI EN 302 208 (2W
ERP). Different surface materials may have an effect on performance. In
real environment the read range may also be much longer.

MECHANICAL SPECIFICATION

Tag materials
High quality engineering plastics.
Weight
31 g
Delivery format
Single
Amount in box
100 pcs
Dimensions
155mm x 26mm x 14,5mm / 6.1” x 1.02” x 0.57”

ENVIRONMENTAL RESISTANCE

Operating temperature
-35°C to +85°C / -31°F to +185°F
Ambient temperature
-35°C to +85°C /-31°F to +185°F
IP classification
IP68
Weather ability
Good, including UV-resistance and sea water
Chemical resistance
No physical or performance changes in:
– 168h Motor oil exposure
– 48h Salt water (salinity 10%) exposure
– 48h Sulfuric acid (10%, pH 2) exposure
– 48h NaOH (10%, pH 13) exposure
Generally good resistance with moderate concentrations
of acids, alcohols, alkalis, detergents and cleaners.
Acetone should be avoided
Expected lifetime
Years in normal operating conditions


Values in the table are the best recommendations; resistance against
environmental conditions depends on the combination of all influencing
factors, exposure duration and chemical concentrations. Thus, product’s
final suitability for certain environmental conditions is recommended to
be tested. Contact Confidex for more specific information.

ORDER INFORMATION

INSTALLATION INSTRUCTIONS

Confidex SurvivorTM can be attached with several fixing
methods:


1. High performance acrylic adhesive (not included
by default)


When background adhesive is ordered the tag is delivered
with adhesive attached. Clean and dry the surface for
obtaining the maximum bond strength. Ideal application
temperature is from +21°C to +38°C (+70°F to +100°F),
bond strength can be improved with firm application
pressure and moderate heating from +38°C to +54°C
(+100°F to +130°F). Installation at temperatures below
10°C (50°F) is not recommended.


2. Other adhesive fixings


• Polyurethane adhesives
• Epoxies
• Silicone sealants


Structural adhesives like 3M DP410 provide very high bond
strength and resistance against mechanical stress. When
tag is attached with sealant adhesive, insert a layer of
sealant under the tag and press the tag on the surface.
Increase the bond by adding extra sealant from the tag
holes. Insert maximum 2mm layer of adhesive under the
tag. Please refer to adhesive supplier for exact fixing
instructions.

3. Screw or pop rivet


Mechanical fixing is
recommended to be used in
every application that includes
risk for high mechanical stress
or low temperature during tag
fixing. Mechanics are designed
for M5 sized screw. Refer the
dimensional picture for screw
selection.


4. Cable tie


Confidex Survivor™ has specific design that allows also
plastic or metallic cable ties to be used for fixing.
Maximum width of tie is 4mm. Please see picture below
for an example.

PERSONALIZATION OPTIONS

Pre-encoding
• Customer specific encoding of EPC or user
memory. Locking permanently or with password.
Customized data label
• Customer specific layout including logo, text,
numbers, barcodes etc.
Customized laser engraving
• Customer specific layout including logo, text,
numbers, barcodes etc.

ORDER INFORMATION

Product number: 3001137
Product name: Confidex SurvivorTM G2iM+ ETSI
Product number: 3000856
Product name: Confidex SurvivorTM M4QT FCC


For other versions, additional information and technical
support contact Confidex Ltd.

DISCLAIMER
THE MATERIALS, PRODUCTS AND SERVICES ARE SOLD SUBJECT TO ITS STANDARD CONDITIONS OF
SALE, WHICH ARE INCLUDED IN THE APPLICABLE DISTRIBUTOR OR OTHER SALES AGREEMENT.
ALTHOUGH ANY INFORMATION, RECOMMENDATIONS, OR ADVICE CONTAINED HEREIN IS GIVEN
IN GOOD FAITH, CONFIDEX MAKES NO WARRANTY OR GUARANTEE, EXPRESS OR IMPLIED, (i) THAT
THE RESULTS DESCRIBED HEREIN WILL BE OBTAINED UNDER END-USE CONDITIONS, OR (ii) AS TO
THE EFFECTIVENESS OR SAFETY OF ANY DESIGN INCORPORATING ITS PRODUCTS, MATERIALS,
SERVICES, RECOMMENDATIONS OR ADVICE. EXCEPT AS PROVIDED IN CONFIDEX STANDARD
CONDITIONS OF SALE, CONFIDEX AND ITS REPRESENTATIVES SHALL IN NO EVENT BE RESPONSIBLE
FOR ANY LOSS RESULTING FROM ANY USE OF ITS MATERIALS, PRODUCTS OR SERVICES DESCRIBED
HEREIN.

Each user bears full responsibility for making its own determination as to the suitability of
Confidex products, materials, services, recommendations, or advice for its own particular use.
Each user must identify and perform all tests and analyses necessary to assure that its finished
systems incorporating Confidex products, materials, or services will be safe and suitable for use
under end-use conditions. Nothing in this or any other document, nor any oral recommendation
or advice, shall be deemed to alter, vary, supersede, or waive any provision of this Disclaimer,
unless any such modification is specifically agreed to in a writing signed by Confidex.